hello everyone.
iam devarajan.k currently pursuring M.Tech in Engineering Design in Amrita University and doing projects on hot rolling of thick plates.For FEm simulation iam using ABAQUS software. After material rolled, i want to quench that material into water or some other material. i dont know how to do this in abaqus. please guide me if any one know this. please
With Regards
Devarajan.K
»
- kdevarajanmts's blog
- Log inorregisterto post comments
- 6477 reads
Comments
Quenching
iam devarajan.k currently pursuring M.Tech in Engineering Design in
Amrita University and doing projects on hot rolling of thick plates.For
FEm simulation iam using ABAQUS software. After material rolled, i want
to quench that material into water or some other material. i dont know
how to do this in abaqus. please guide me if any one know this. plea
Hello dear
Hello dear kdevarajanmts,
you can find how you can quench your material on the manuel of ABAQUS. Here is it:http://www.asminternational.org/content/ASM/StoreFiles/06700G_Index.pdf
best regards
Rene
Respected Sir Thanks for
Respected Sir
Thanks for your guideance.This book very useful to me. i gone through that book, but iam not found abaqus manual in this. please kindly provide that one.
Quenching
Hello,
you need to use FILM
see: “Thermal loads,” Section 30.4.4 of the Abaqus Analysis User's Manual
also:
1.6.4 Quenching of an infinite plate
in the Benchmark Manual
------------------------------------------
Ruhr-University
Bochum
Germany
abaqus
i am modelling impact on composit (CFRP) sadwitched between aluminium plates in FEM using ABAQUS6.10.On submitting the job the errors-
1-ELASTIC CONSTANTS ENTERED ARE NOT PHSICALLY REASONABLE:-CHECK FOR POISSION RATIOS.
2- ELASTIC CONSTANTS ENTERED ARE NOT PHSICALLY REASONABLE.WORK DONE BY ALL STRAIN COMPONENTS MUST BE PSITIVE.CHECK FOR POISSION RATIOS.
IF ANY ONE HAVE ANY CLU/SOLUTION PLEASE SUGGEST.THANK YOU.